Renoscope EndoGlance® 4 mm 70°, арт. 6000-44R, — Hard endoscope, working length 175 mm For the use of a radar and visual escort for LOR interventions 70° allows the inclination to be reoriented when the endoscope is turned.
Design and features
Workspace 4 mm are taken into account in the choice of access; the field of vision is 85° in the direction of observation 70°.
The core-line optical system supports the wide-format image of Full HD and is equipped with highly focused optical elements.
The integrated fibre-optic canal is bringing light to the inspection area, and the distal sapphire lens protects the optical tip.
Ocular diameter 31.7 mm is designed to connect with the appropriate adapter of the camera 90°.
Olympus light-water cable standards maintained, Karl Storz, Wolf and Endomedium when using appropriate compounds.
Sterilization, including autoclavation, is provided for vapour, chemical and gas sterilization 134 °C for the maintenance of the records.
Clinical use
Renoscopes are used for nose and endoscopy examination after diarrhea surgery. Sloppy optics shall be selected from the location of the inspection area and the access anatomy.
The monitor is designed to be visualized Video camera EndoGlance® V AF. Lighting EndoLamp® (Current model) compatible light-water cable.
Technical specifications
| Type | The Rinoscope for the Forequarter Side Vision 70° rigid, high resolution, lens rod with integrated fibre-optic lighting channel |
| Scope | Renoscopy |
| Classification of the medical product | Endoscope with rigid input designed for visual examination and treatment of bow and/or nasal throat. The device shall be inserted into the body through the nostril or mouth cavity during phinoscopy and/or ear/nose interference |
| Working section diameter, mm | 4 |
| Working length, mm | 175 |
| Angle of observation, degrees | 70 |
| Color code | yellow |
| Angle of vision, degrees | 85 |
| Series | EndoGlance |
| Support for wide-format high-figurity FULL HD | Yes |
| High-precision optical-cell centralization | Yes |
| Light-sensitive colour filters | Yes |
| Insulated condensors | Yes |
| Distal protective sapphire lens | Yes |
| Angle of installation of a connector to connect light-water cables, degrees | 90 |
| Diameter of the ocular, mm | 31.7 |
| Supported light-wire cable standards | Olympus, Karl Storz, Wolf, Endomedium |
| Instruction on the processing and sterilization of the instrument | Yes |
| Individual packaging with impact-resistant spoon under the shape of an article | Yes |
| Permitted sterilisation methods | Steam, chemical and gas |
| Allowable autoclavation program | Temperature 134°C, Pressure 2 bar, Impact time 5 min, Sterilisation cycle 30 min |
Supplied components
| арт. 6000-44R, Renoscope 4 mm 70° EndoGlance® | 1 pc. |
| Switcher under lighting cable Endomedium, K. Storz, Olympus | 1 pc. |
| The switch to Wolf's lighting cable | 1 pc. |
| Box of packaging | 1 pc. |
| Passport | 1 pc. |
Alternative names
- Endoscope hard 4 mm 70° autoclavic with sapphire lens, optical pyroscopic 4 mm, rinoscope operating 4 mm 70 gr., 4-70°, a hard-line, hard-lined optical with integrated fiber-optic lighting channel 4 70, laur Endoscopy 4 mm, rinoendoscope, endoscope nasal, endoscopy for upper-flural pasus
- РН402718С — Able line tube (for phino and artroscopy, d4 mm, 70°)
- Т-35-70 — Tube optical hard "Wing" A 4-70
- 9740.123 — The tube shall be optical (Artroscopy, Rinoscopic) ТОАР-016 Diam. 4 mm, observation angle 70°
- 00-1124-05 — Transluminal endoscopy toolbox laparoscopic-assisted interventions - "ЭСТЭН" Under ТУ 32.50.13-001-65500831-2019: endoscope d=4 mm (Spoon.5) (00-1124-05)
- PE525A — LOR Endoscope/Artroscope ø 4.0 mm 70° 180 mm
- 7230CA — Synops of hard HOPKINS, type size: direction of observation 70°, diameter 4 mm, length 18 cm
- WA96205A — Sine-scopy telescope, HD, autoclavic, 4 mm, direction of review 70°
The purchase of products starts with a manager ' s consultation. Please describe your tasks or send a list of the items selected, and we will help you to select the components and check the compatibility of the system.
Press "Ask KP" in the product card, write on endo@endo.ru Or call on the phone +7 (843) 207-02-10. Please specify the names or articles of the product, the quantity, organization details and contact details.
Estimated delivery date — from 2 up to 45 It depends on the availability of products, the ordering and the loading of production.
The manager will agree on a specific time frame for your order. If the equipment is required by a specific date, report it when you are in circulation.
Yes Endomedium Develops and produces medical equipment with 1991 Production by the GCO Endomedium+».
The site only contains our products. All the trademarks here are owned by the public Endomedium. Registration and other documents issued under the «Documents».
Yes, our equipment and tools that are required to be registered as medical items have registered documents.
Documents are available in The appropriate section of the site. If you need help with the search, give me the name, model or artiful of the product — a specialist will pick up the documents related to it.
Guarantee and post-insurance maintenance is performed by an authorized service centre Endomedium-Services, licensed for maintenance and repair of medical equipment.
Treatment and maintenance materials are available under the following headings «Service Centre».
Contact the service centre: service@endo.ru, +7 (843) 249-00-45. Please specify the model and serial number of the product, describe the malfunction and leave contact details for feedback. Please attach photographs or videos if possible.
The specialist will specify the course of action and the delivery of the product Requirements for the preparation of service equipment.