Artroscope EndoGlance® 4 mm 0°, арт. 6000-40A, — Hard endoscope, working length 175 mm For artroscopic visualization. Direct optics provide a view along the endoscope axis.
Design and features
Work diameter 4 mm and length 175 mm determine the choice of compatible tube and access.
Field of vision 60° Combined with the direction of observation 0°; These parameters describe the different sides of the survey geometry.
The core-line optical system supports a wide-format image of Full HD in the relevant video system.
The built-in fibre-optic lighting channel brings light to the inspection area.
Ocular diameter 31.7 mm Video cameras are used with suitable adapter; the light-ray connector is at an angle 90°.
Sterilization, including autoclavation, is provided for vapour, chemical and gas sterilization 134 °C for the maintenance of the records.
Clinical use
Artroscopy is used to examine joints and visual support operations. When the knee joint is artroscopy, the manis, joint cartilage, sinus and ligament structures are evaluated; the healing manipulations are performed by separate tools.
The image is designed to be transmitted to the monitor Video camera EndoGlance® V AF, for lighting through a compatible light-lighting device - lighting EndoLamp® (Current model).
Technical specifications
| Type | Direct vision 0° rigid, high resolution, lens rod with integrated fibre-optic lighting channel |
| Scope | Artroscopy |
| Classification of the medical product | A rigid injectable Endoscope designed to visually examine and treat the inner joint, e.g. knee, shoulder, elbow, and enter the body through an artificial opening created by an incision during the arthroscopy procedure (Authorized clinical use of medical product) |
| Working section diameter, mm | 4 |
| Working length, mm | 175 |
| Angle of observation, degrees | 0 |
| Color code | Green |
| Angle of vision, degrees | 60 |
| Series | EndoGlance |
| Support for wide-format high-figurity FULL HD | Yes |
| High-precision optical-cell centralization | Yes |
| Light-sensitive colour filters | Yes |
| Insulated condensors | Yes |
| Distal protective sapphire lens | Yes |
| Angle of installation of a connector to connect light-water cables, degrees | 90 |
| Diameter of the ocular, mm | 31.7 |
| Supported light-wire cable standards | Olympus, Karl Storz, Wolf, Endomedium |
| Instruction on the processing and sterilization of the instrument | Yes |
| Individual packaging with impact-resistant spoon under the shape of an article | Yes |
| Permitted sterilisation methods | Steam, chemical and gas |
| Allowable autoclavation program | Temperature 134°C, Pressure 2 bar, Impact time 5 min, Sterilisation cycle 30 min |
Supplied components
| арт. 6000-40A, Artroscope 4 mm 0° EndoGlance® | 1 pc. |
| Switcher under lighting cable Endomedium, K. Storz, Olympus | 1 pc. |
| The switch to Wolf's lighting cable | 1 pc. |
| Box of packaging | 1 pc. |
| Passport | 1 pc. |
Accessories
Alternative names
- Endoscope hard 4 mm 0° autoclavic with sapphire lens, optical arthropscopic 4 mm, artroscope operational 4 mm 0 gr., 4-0, a hard-line, hard-lined optical with integrated fiber-optic lighting channel 4 0, artro endoscope 4 mm, a direct vision arthropscope
- Т-34 — Tube optical hard "Wing" A 4-0
- 9740.119 — The tube shall be optical (Artroscopy, Rinoscopic) ТОАР-012 Diam. 4 mm, observation angle 0°
- 00-1124-01 — Transluminal endoscopy toolbox laparoscopic-assisted interventions - "ЭСТЭН" Under ТУ 32.50.13-001-65500831-2019: endoscope d=4 mm (Spoon.1) (00-1124-01)
- 7230 AA - HOPKINS OPERATIONS® Direct vision II 0°, Large, Ø 4 mm, self-clarified
- AR-3355-4000 — Artroscopy HD C-mount, 0°, 4 mm
- PE485A — LOR Endoscope/Artroscope ø 4.0 mm 0° 180 mm
- A40-175-00AC — Artroscope ⌀ 4.0 mm, 0° auto-clubbed
The purchase of products starts with a manager ' s consultation. Please describe your tasks or send a list of the items selected, and we will help you to select the components and check the compatibility of the system.
Press "Ask KP" in the product card, write on endo@endo.ru Or call on the phone +7 (843) 207-02-10. Please specify the names or articles of the product, the quantity, organization details and contact details.
Estimated delivery date — from 2 up to 45 It depends on the availability of products, the ordering and the loading of production.
The manager will agree on a specific time frame for your order. If the equipment is required by a specific date, report it when you are in circulation.
Yes Endomedium Develops and produces medical equipment with 1991 Production by the GCO Endomedium+».
The site only contains our products. All the trademarks here are owned by the public Endomedium. Registration and other documents issued under the «Documents».
Yes, our equipment and tools that are required to be registered as medical items have registered documents.
Documents are available in The appropriate section of the site. If you need help with the search, give me the name, model or artiful of the product — a specialist will pick up the documents related to it.
Guarantee and post-insurance maintenance is performed by an authorized service centre Endomedium-Services, licensed for maintenance and repair of medical equipment.
Treatment and maintenance materials are available under the following headings «Service Centre».
Contact the service centre: service@endo.ru, +7 (843) 249-00-45. Please specify the model and serial number of the product, describe the malfunction and leave contact details for feedback. Please attach photographs or videos if possible.
The specialist will specify the course of action and the delivery of the product Requirements for the preparation of service equipment.