Reviews
Endoscopic video camera EndoGlance® V AF Vario combines the image of ULTRA HD 4K, Varyofocular lens 14–32 mm and super fast auto-focused for 0,5 It is recommended that a variable focus distance be used when working with rigid endoscopy diameters less than 5 mm, including thin laparoscope And a specialized optics for gynaecology, urology, artroscopy and otolaringology.
Varyofocular lens for endoscopy smaller than 5 mm
A variable focal distance lens 14–32 mm The image size of the endoscope is aligned with the camera field. If the image of the small diameter optics only takes a part of the screen, the change in focus distance helps to increase it optically and reduce the dark fields around the edges. The surgeon becomes more comfortable with the anatomical structures and working parts of the tool.
Range 14–32 mm The doctor selects the overall overview and detail ratio required during the current intervention phase.
Super-rapid automatic focus
EndoGlance® V AF Vario is equipped with a focus car with a sharper focus for 0,5 The surgeon selects the object and starts focusing the button on the headhead, including after changes in scale, endoscopy movement or tissue distance.
The transition between inspection sites requires less manual action: the surgeon or assistant restores the clear image by one press, while keeping the video-heading at a convenient grip.
Deepening sharpness
The increased sharpness depth allows for simultaneous observation of sharp structures at different distances from the endoscope, which helps to compare anatomic orientations and the position of the tool, and less to adjust focus when a slight change in observation distance occurs.
The scale settings without moving the endoscope
The variable focus distance allows the image to change its scale by keeping the distal end of the endoscope position. This is convenient when operating in a limited space, when it is important to hold the selected direction of view and to observe the interaction of the tool with the tissues.
Processor for rapid processing of video signal
8-Nuclear heterogeneous 64-The bit graphic processor provides high-end video processing, faster processing of the scene luminance changes and color saturation settings to a level convenient to the operating surgeon. This helps to adapt the image to the movement of the optics and to change the observational conditions.
Visual delay less 70 milliseconds helps a doctor compare the movement of the tool to the image on the monitor while performing exact manipulations.
Color Transfer BT.2020 and 16 Color adjustment steps
Support for Color Space BT.2020 The doctor receives additional colour guidelines when examining the receptacles, the surface of the tissue and the areas of manipulation.
16 Color adjustment steps allow for color selection, taking into account the optical input used, the intervention direction and the surgeon's preferences.
Backlight sensor
The backlight sensor provides increased sensitivity and image improvement with low lighting. This is useful in working with small diameter optics and in examining less illuminated areas: it is easier for a doctor to consider details with limited light input.
Image 4K and optical resolution of more than 1600 TV line
ULTRA HD resolution 4K 3840 × 2160 Pixels and optical resolution more 1600 The TV line provides detailed representation of the surface of the tissue and vascular pattern.
Combined with a selection of optical scales 4K Helps a doctor to consider small vessels, tissue boundaries, needle tip and work parts of the tool when using small diameter endoscopy.
Intelligent E-Glance image processing algorithms
E-Glance algorithms allow for the selection of image processing under examination conditions and the current task of the doctor:
E-HLC — Anthiblik». Reduces the brightness of the liquid and glossy tools by making the field's observation more comfortable.
E-BLC — Lighting of Dark Places. Helps to view structures in dark peripheral areas with complex anatomy.
E-smoke — Antidesm». Reduces the effect of surgical smoke on the image, improving visibility in electrosurgery.
E-REDE — Red Suppression. Reduces the red content in the over-representation areas.
E-detail — Discharge of receptacles. Increases the visibility of the vascular pattern, including small receptacles, for more detailed inspection.
E-moire — Anthimoire». Reduces the moire artifacts when working with compatible fibrooptic endoscopy.
E-POP — Image Comparison. At the same time, it produces raw and processed images, allowing the doctor to evaluate the results of the algorithm.
E-PIP is an additional video source. Puts on the screen an image of a compatible external source connected to the camera.
The selected algorithm can be assigned to the headhead button. E-smoke is a supplement to the physical removal of smoke.
The function and its possibilities are described in detail on the page «Endoscopy image processing algorithms E-Glance».
Ten pre-established regimes
Ten presets cover different areas of minimally invasive surgery and diagnostics, including laparoscopy, thoracoscopy, hysteroscopy, urology, rhinoscopy and arthroscopy. The presets help prepare the image for the procedure more quickly. Users can adjust the settings to suit the optics and the clinician’s preferences.
Three programmable head-head buttons
The three programmable videohead buttons can assign any function available on the camera menu. The doctor selects the most requested command and adjusts the control to his preferences and intervention tasks:
Select and incorporate any E-Glance intellectual algorithm;
The image is increased and reduced;
Launch and stop video recording;
Photo production;
and other camera menu functions.
When working with small endoscopy, a doctor can restore sharpness after changing scale, set up a brightness or save the image directly from the headhead. Access to selected functions without contacting the camera block is convenient for both the surgeon and the assistant holding the endoscopy.
Easy videohead with autoclavic ability
Special design and videoheading material reduce its weight and facilitate retention of endoscopy in long-term operation.
The videohead has a degree of protection IPX8. Liquid disinfection and autoclapping are provided for in accordance with the facilities, treatment and treatment conditions established by the operating manual.
Video equipment 4K, Full HD and analog video
Provision is made for the connection of compatible monitors, recording devices and image transmission equipment:
Video output 4K — HDMI 2.0, DisplayPort (DP), 4 × 12G-SDI;
Full HD video output — 3G-SDI, DVI-D;
Analog Video Outputs — S-Video, CVS.
The camera also has a fiber-optic exit to transmit the video signal 12G. The diversity of interfaces allows for the selection of a way to connect to compatible operating, training or video-broadcasting equipment.
Documentation and recording of audio comments
The camera supports the video 4K frequency 30 Humans per second or Full HD at frequency 60 The internal storage device is a volume storage device 2 TB and the connection of external USB carriers allow for the preservation of documentation, operations review and training materials.
The microphone is designed to record audio comments and sound from the operating room. The doctor can explain the anatomy and the actions being performed to follow up the intervention. In the event of a telecast, the camera is connected to a compatible video and sound transmission system.
Pick up Combinable laparoscope and other rigid endoscopic optics with standard oculars with reference to diameter, direction of intervention and required scale of the image.
Technical specifications
| Type | Endoscopic video camera of the ultra-high precision ULTRA HD colour image with automatic focus |
| Maximum resolution, pixels | 3840 Horizontal, 2160 Vertical |
| Sensor | 1/2.8 CMOS |
| Visual delay, ms | 70 |
| Image sensor, unit. | 1 |
| Color Standard | BT.2020 |
| Focus | Electronic automatic, push button |
| Processor Type | 8-Nuclear heterogenic processor 64 bat |
| Party ratio | 16:9 |
| Signal/Noise ratio, dB | 50 |
| Scanner Method | Progressive Distillation 50/60P |
| Minimum illumination | < 1 Luxe, equivalent F1.6 |
| Videohead buttons | Electronic automatic focus, freely programmable 3 units. |
| Optimal resolution, tv lines | more than 1600 |
| Indirect resolution 4K 3840×2160 Pixels | Yes |
| Objective | Changed focus distance |
| Focus distance, range, mm | 14-32 |
| Head size, with optical adapter, D x V x S, mm | 145 x 55 x 50 |
| Clamp mechanism | Standard Occulus adapter |
| Camera head temperature,℃ | No more than 37 |
| Scope | Laparoscopy, Toracoscopy |
| Video equipment 4K | HDMI2.0, DP, 4x12G-SDI |
| FULL HD Videos | 3G-SDI, DVI-D |
| Videos | S-Video, CVBS |
| FULL HD Video | 3G-SDI, DVI |
| Other interfaces | Pedal, RS232, Microphone, LAN, 4xUSB Rear Panel, 1xUSB Front panel |
| Control panel | Activation/off. Video, photo, white balance, brightness, menu |
| User scenes | 10 I'm gonna get you a setup scene |
| Digital Zoom | 5x increase, 50 Steps; 0.5 decrease, 5 Steps |
| Level luminance adjustment, unit. | 10 |
| Image modification | Horizontal turn, Vertical turn, Mirror display |
| Documentation | Image JPG/BMP 3840x2160, Video 3840х2160, 30fps or 1920х1080, 60Hz Mpeg-4 H.264 |
| Image Functions | E-Glance algorithms |
| Storage system | In-line hard drive 2 Tb, External storage device |
| Inter-tool communication | EndoGlance Net |
| Automatic white-base installation by manual object | Yes |
| The display luminance control buttons on the control unit | Yes |
| Video image button on control | Yes |
| Photo image button on the control unit | Yes |
| The digital video signal recorder on the flash drive is stored in the camera housing | Yes |
| Support for external video and photo storage | Yes |
| External storage interface version | USB 3.0 |
| The Sound Commenting Function | Yes |
| Microphone connection | Yes |
| Camera head cable | 280 cm Highly flexible |
| Camera head handling | Liquid, ethylene oxide, plasma hydrogen peroxide |
| Head protection | IPX8 |
Supplied components
| Video signal processing unit EndoGlance® ULTRA HD AF | 1 pc. |
| 32356, Head of the video camera with variable focus distance and auto-focused function | 1 pc. |
| 20046, Power cord | 1 pc. |
| 5015-72, HDMI-HDMI cable | 1 pc. |
| 5015-73, HDMI-DVI cable | 1 pc. |
| 5015-70, BNC-BNC cable (12G SDI) | 1 pc. |
| Operating Manual | 1 pc. |
| Flash storage device 128 GB | 1 pc. |
Alternative names
26.60.12.119-00000372, Video camera endoscopy EndoGlance® ULTRA HD AFV ТУ 26.60.12-018-47086606-2023
The purchase of products starts with a manager ' s consultation. Please describe your tasks or send a list of the items selected, and we will help you to select the components and check the compatibility of the system.
Press "Ask KP" in the product card, write on endo@endo.ru Or call on the phone +7 (843) 207-02-10. Please specify the names or articles of the product, the quantity, organization details and contact details.
Estimated delivery date — from 2 up to 45 It depends on the availability of products, the ordering and the loading of production.
The manager will agree on a specific time frame for your order. If the equipment is required by a specific date, report it when you are in circulation.
Yes Endomedium Develops and produces medical equipment with 1991 Production by the GCO Endomedium+».
The site only contains our products. All the trademarks here are owned by the public Endomedium. Registration and other documents issued under the «Documents».
Yes, our equipment and tools that are required to be registered as medical items have registered documents.
Documents are available in The appropriate section of the site. If you need help with the search, give me the name, model or artiful of the product — a specialist will pick up the documents related to it.
Guarantee and post-insurance maintenance is performed by an authorized service centre Endomedium-Services, licensed for maintenance and repair of medical equipment.
Treatment and maintenance materials are available under the following headings «Service Centre».
Contact the service centre: service@endo.ru, +7 (843) 249-00-45. Please specify the model and serial number of the product, describe the malfunction and leave contact details for feedback. Please attach photographs or videos if possible.
The specialist will specify the course of action and the delivery of the product Requirements for the preparation of service equipment.