КТРУ 32.50.50.190-00000450 — «The electrical surgical argon system is enhanced." Such a system is selected when, along with conventional electrosurgical effects, an argon-enhanced coagulation is required.
WizardCut® Argon, арт. 5013-09, The model contains monopolar and bipolar effects with argon-enhanced coagulation regimes Endomedium specified КТРУ 32.50.50.190-00000450.

What uses an argon-enhanced electrosurgery
The energy is transferred via ionized argon in the case of an argon-enhanced coagulation. This is different from the contact work of a conventional electrode and requires the tools for it. The method is determined by the surgical task, type of access and characteristics of the tissue being processed.
For a physician, the availability of argonal modes expands the range of coagulation techniques within the limits of the machine ' s function, while the argon regime does not remove the limits of electrosurgery and does not make the tool universal for any anatomical area.
What Combines WizardCut Argon
The system supports monopolar cutting and coagulation, bipolar effects, special regimes for resectoscope This allows for the examination of the apparatus when equipped with a multidisciplinary operating unit, prior to agreeing on the necessary regimes and a toolbox.
| System possibility | What to Consider in Selection |
|---|---|
| Monopolar cutting and coagulation | Designation of active instrument, connection cable and neutral electrode |
| Bipolar cutting and coagulation | The compatibility of the instrument with the selected effect |
| Modes for resectoscope | Performance of the working unit, electrode and liquid environment requirements |
| Bipolar artroscopic absulation | Compliance of mode with the type of artroscopic electrode |
| MGOAG ARGON LAP | Individual argon mode; specified rated power — 100 W |
| MGOAG ARGON ENDO | Individual argon mode; specified rated power — 50 W |
| Gas contour | Argon source, chimney, hose and connections |
| Performance monitoring | Status indicator, neutral electrode control and no argon alarm |
The power values in the table refer to the characteristics WizardCut Argon: They are not recommended facilities for a particular operation and do not replace the characteristics of the relevant item КТРУ.
Why Gas outline needs to be agreed in advance
The argon part of the system requires a suitable gas source and a harmonized connection WizardCut Argon gas inlet pressure specified 0,5 MPa and maximum volume flow 4 L/min. These are machine parameters that should be taken into account when selecting accessories, not universal clinical application settings.
The card lists a high pressure hose, argon pressure control device and cylinder. Special marks and actual delivery compositions need to be confirmed in the commercial proposal. It is particularly important to determine in advance which components already exist in the medical organization and whether they are suitable for the selected system.
Electrical, cable and control
The operation in argon mode requires appropriate electrodes and accessories; the presence of a conventional monopolar separation does not confirm the ability to supply gas through any instrument. The length of the instrument, the type of access, the connection to the gas contour and the electrical connection are separately checked.
For other modes selected electrosurgical cables In monopolar configuration, the same considerations are also taken into account neutral electrode. WizardCut Argon is assembled by a three-klav pedal; its function distribution is aligned with the selected operating modes.
Different from the electrosurgery system without argon mode
The basic task of an electro-surgery generator is to provide the specified cutting and coagulation. The reinforced argon performance also includes the ability to control the gas supply and the associated effects. Therefore, the comparison of such machines only by maximum power is incorrect: there is a need to compare functional modes and a fully complete operating loop.
If no argon effects are required, study Electrical surgery system WizardCut. A separate material on monopolar and bipolar regimes has been prepared for her, resectoscope Division helps to select performance for the real task of the office.
How to prepare a request for supply КТРУ 32.50.50.190-00000450
Please specify the transaction profile, the necessary argon and conventional electrosurgery modes, the types of tools used and the conditions for gas connection. Please list separately in the specification the generator, pedal, electrode, cables, neutral electrode and gas accessories. This allows for testing the kit before delivery.
On the website for WizardCut Argon is specified as registration Г004-00110-00/03363682. Performance description and list of supplies are compared with registration and maintenance documents and procurement requirements are compared with the relevant revision КТРУ. Specialists Endomedium Help harmonize the argon-enhanced system for your O.R.