WizardCut® Argon argon-enhanced electrosurgical system
Argon integrated system
27 effects
Precise effect settings
New Digital Signal Processing Processors
Steady parameters over the power range
Universal three-clavic pneumatic pedal
E.S.C.S
High performance in liquid environments
Electrical coagulator WizardCut® Argon Endomedium, High output and high functional capacity and available in all areas of medicine: abdominal surgery, plastic surgery, gynaecology, laparoscopy, Transurethral resection, arthroscopy, proctology, endoscopy, veterinary science, etc.REGIMES OF "REVISION»
BCUT UNI Bipolar Cut Universal mode, power adjustment available: features and recommended applications: cutting tissue with different electrical conductivity with a regulated level of hemostating effect.
BCUT GU bipolar cutting Special mode, power adjustment available: features and recommended applications: bipolar cutting regime for hysteroresectoscope and TRM optimized for isotonic liquid media and recommended for application in urology and gynaecology for cystoresctoscopy and hysteroresectoscope. recommended tools: Special bipolar electrodes for cystoresctoscopes and hysteroresectoscope.
BCUT A1 Bipolar absulation Special regimes, power adjustment is available. Specific features and recommended applications: bipolar atroscopic absulation regime. Recommended tools: special bipolar electrodes with small artroscopy space.
BCUT A2 Bipolar absulation Special regimes, power adjustment is available. Specific features and recommended applications: bipolar atroscopic absulation regime. Recommended tools: special bipolar electrodes with medium-size artroscopy space.
BCUT A3 Bipolar absulation Special regimes, power adjustment is available. Specific features and recommended applications: bipolar artroscopic absulation regime. Recommended tools: special bipolar electrodes with large artroscopy space.
MCUT MIN monopolar cutting Special mode, power adjustment is available. Specific features and recommended applications: cutting of cover tissue with minimal notice of the scar after healing with primary tension. Recommended tools: exclusively thin needle electrodes with a diameter not exceeding 0.2 mm.
MCUT CLEAR monopolar cutting Universal mode, power adjustment available. Features and Recommended Application: Cutting any tissue with good electrical conductivity (For example, muscle or vascular tissue) with the minimum carbonation and the minimum possible hemostating effect. Recommended tools: electrodes for dissipation.
MCUT MIX1 monopolar cutting Special mode, power adjustment is available. Specific features and recommended applications: cutting tissue with the lowest possible hemostasis in cases where high-efficiency cut control is required. Endoscopy interventions for papillotomy / sphinctomy are recommended. Recommended tools: Special flexible monopolar electrodes for papillotomy / sphinctomy.
MCUT MIX2 monopolar cutting Special mode, power adjustment is available. Specific features and recommended applications: cutting tissue with well-produced controlled hemostasis in cases where high-efficiency cut control is required. Endoscopy interventions are recommended for application to polyectomy. Recommended tools: Special flexible monopolar electrodes loops for polyectomy.
MCUT GU monopolar cutting Special mode, power adjustment available: Special features and recommended applications: monopolar cutting regime for hysteroresectoscope and TUR (1) optimized for non-isotonic liquid media and recommended for application in urology and gynaecology for cystoresctoscopy and hysteroresectoscope. recommended tools: Special monopolar electrodes for cystoresctoscopes and hysteroresectoscope.
MCUT G1 monopolar cutting with hemostasis Universal mode, power adjustment available: Specific features and recommended applications: cutting tissue with different electrical conductivity: for high-density tissues.
MCUT G2 monopolar cutting with hemostasis Universal mode, power adjustment available: Specific features and recommended applications: cutting tissue with different electrical conductivity: for fabrics with mean bleed capacity.
MCUT G3 monopolar cutting with hemostasis Universal mode, power adjustment available: Specific features and recommended applications: cutting tissue with different electrical conductivity: for low-denial tissue. Recommended tools: electrodes for disseminating tissue.
COAGUILATIONS" REGIMES»
BGOAG MIK bipolar coagulation Universal mode, power adjustment is available. Specific features and recommended applications: bipolar coagulation without carbonization. Recommended tools: bipolar tools: puffets for microsurgery.
BGOAG MED Bipolar Coagulation Universal mode, power control is available: features and recommended applications: bipolar coagulation with minimum carbonization. Recommended tools: bipolar instruments: pinches, pints, clamps, dissectors.
BGOAG MAK bipolar coagulation Universal mode, power adjustment available: features and recommended applications: rapid bipolar coagulation with moderate carbonation. Recommended tools: bipolar instruments: pints, pints, clamps, dissectors.
BGOAG GU Bipolar coagulation Special mode, power adjustment available: features and recommended applications: bipolar coagulation regime for hysteroresectoscope and TRM optimized for isotonic liquid media and recommended for application in urology and gynaecology for cystoresctoscopy and hysteroresectoscope. recommended tools: Special bipolar electrodes for cystoresctoscopes and hysteroresectoscope.
BGOAG A Bipolar coagulation Special mode, power adjustment available: features and recommended applications: Bipolar Artroscopic Coagulation is recommended for use in artroscopy.
BGOAG LIG bipolar coagulation Special regime, several pre-established levels: Specific features and recommended application: the regime is intended to replace mechanical leachation of receptacles with a diameter prior to the first entry into the second phase of the second phase of the second phase of the second phase of the second phase of the second phase of the second phase of the second phase of the second phase of the second phase of the second phase of the second phase of the second cycle 7 mm during the process of thermal electrically-ligagation between the instrument's blades, the liquid is being equidisposed and the proteins of the vessel being treated denaturized, creating a homogeneous collagen structure that is reliable for the opening of the receptacle.
MGOAG CLEAR monopolar coagulation Universal mode, power adjustment is available. Specific features and recommended applications: coagulation without carbonization of the tissue and with a minimum probability of electrode sticking to the tissue. Compared to other coagulation regimes, coagulation depth is increased. To maximize coagulation depth, select lower power and coagulate over a longer period of time. If coagulation is required for a shorter period of time, then set a higher power limit. Recommended in all cases requiring reliable coagulation with a sufficiently deep penetration of the effect, and in cases where electrode attachment to the tissue prevents effective coagulation. Recommended tools: instruments for coagulation with a large contact area.
MGOAG SPRAY Monopolar coagulation Special mode, power adjustment available: Specific features and recommended applications: Uncompressed coagulation of extensive surfaces with diffuse bleeding at low penetration depth. Recommended tools: coagulation tools with large and medium contact area.
MGOAG GU Monopolar coagulation Special mode, power adjustment available: specifics and recommended applications: monopolar coagulation regime for hysteroresectoscope and TRM optimized for non-isotonic liquid media and recommended for application in urology and gynaecology for cystoresctoscopy and hysteroresectoscope. recommended tools: Special monopolar electrodes for cystoresctoscopes and hysteroresectoscope.
MGOAG UNI1 Monopolar coagulation Universal regimes, power adjustment is available. Specific features and recommended applications: rapid coagulation with moderate carbonation of tissue. Recommended in all cases requiring rapid coagulation: coagulation with minimum carbonation of tissue. Recommended tools: coagulation tools with large and medium contact area.
MGOAG UNI2 Monopolar coagulation Universal regimes, power adjustment is available. Specific features and recommended applications: rapid coagulation with moderate carbonation of tissue. Recommended in all cases requiring rapid coagulation: standard cagulation with moderate carbonation of tissue. Recommended tools: high- and medium-point coagulation instruments.
MGOAG UNI3 Monopolar coagulation Universal regimes, power adjustment is available. Specific features and recommended applications: rapid coagulation with moderate carbonation of tissue. Recommended in all cases requiring rapid coagulation: enhanced fast coagulation with slightly higher carbonation of tissue. Recommended tools: high- and medium-point coagulation instruments.
MGOAG ARGN LAP Monopolar coagulation Special mode for handling argon, power adjustment is available. Specific features and recommended applications: contactless coagulation of surfaces with diffuse bleeding at low penetration depth. Recommended tools: coagulation tools with large and medium contact area.
MGOAG ARGN ENDO Monopolar coagulation Special mode for handling argon, power adjustment is available. Specific features and recommended applications: non-comactive coagulation of wide surfaces with diffuse bleeding at low penetration depth. Recommended tools: coagulation tools with large and medium contact area.
Technical specifications
| Type | Electrosurgery equipment high frequency for monopolar and bipolar coagulation Argon-enhanced |
| Main generation frequency, kHz | 440 |
| Rated power BIPLING / Universal mode / [BCUT UNI], W | 100 |
| Rated power BIPLING / for hysteroresectoscope and TUR is optimized in isotonic liquid media/ [BCUT GU] levels | 10 |
| Rated power of bipolar ABLATION 1 /for arthroscopy, small electrode / [BCUT A1], W | 300 |
| Rated power of bipolar ABLATION 2 /for arthroscopy, medium-size electrode / [BCUT A2], W | 340 |
| Rated power of bipolar ABLATION 3 /for arthroscopy, large electrode / [BCUT A3], W | 330 |
| Nominal power MONPOLULAR RECEIVED / for cover tissues, needle electrodes / [MCUT MIN], W | 50 |
| Nominal power MONPOLULAR RECEIVED / for tissues with good electrical conductivity / [MCUT CLEAR], W | 320 |
| Rated power MONPOLULAR RECEIVED / for papillotomy, sphinctomy / [MCUT MIX1], W | 220 |
| Rated power MONPOLULAR RECEIVED / for polypectomy / [MCUT MIX2], W | 180 |
| Rated power MONPOLULAR RECEIVED / for hysteroresectoscope and TED/ [MCUT GU], W | 300 |
| Rated power MONPOLULAR REFERENCE WITH GEROSTAS 1 /for high-density tissues / [MCUT G1], W | 100 |
| Rated power MONPOLULAR REFERENCE WITH GEROSTAS 2 /for intermediate-carrying tissues / [MCUT G2], W | 200 |
| Rated power MONPOLULAR REFERENCE WITH GEROSTAS 3 /for low-density tissues / [MCUT G3], W | 300 |
| Rated power BIPOLAR COAGUILATION / without carbonation / [BGOAG MIK], W | 15 |
| Rated power BIPOLAR / minimum carbonation / [BGOAG MED], W | 50 |
| Rated power BIPOLAR / moderate carbonation / [BGOAG MAK], W | 130 |
| Rated power BIPLAR / for hysteroresectoscope and TS, optimized for isotonic liquid media/ [BGOAG GU] levels | 10 |
| Rated power BIPLAR / for artroscopy / [BGOAG A], W | 120 |
| Rated power BIPOLAR / for thermoelectric ligation / [BGOAG LIG] levels | 5 |
| Rated power MONPOLULAR COAGUILATION / without carbonation with increased coagulation depth / [MGOAG CHEAR], W | 150 |
| Rated power MONPOLULAR / contactless / [MGOAG SPRY], W | 100 |
| Rated power MONPOLULAR / for hysteroresectoscope and TUR/ [MGOAG GU], W | 120 |
| Rated power MONPOLULAR / with minimum carbonation of fabric / [MGOAG UNI1], W | 150 |
| Rated MONPOL COAGUILATION / with moderate carbonation of fabric/ [MGOAG UNI2], W | 150 |
| Rated MONPOL COAGUILATION / with higher carbonation of fabric/ [MGOAG UNI3], W | 150 |
| Nominal power MONOPOLULATION / non-comactive, for argon/ [MGOAG ARGON LAP], W | 100 |
| Rated power MONOPOLULATION / non-comactive for wide surfaces, for argon/ [MGOAG ARGON ENDO], W | 50 |
| Power control by the electric power holder with button control | Yes |
| Information light and/or audible alarms at break of the passive electrode circuit | Yes |
| Information light and/or audible alarms when no argon is supplied | Yes |
| Stabilisation of output power during alteration of dissectable and coagulated tissue | Yes |
| E.S.C.S | Yes |
| Microcontroller Power independent memory control system, motor test function and machine control | Yes |
| A monopolar and bipolar instrument may be simultaneously operated using a three-clavic pedal | Yes |
| High performance in liquid environments | Yes |
| Nutrition | Power voltage of AC, 100–240 V power supply frequency 50 Hz |
| Range of permissible food stress, B | 100-240 |
| Maximum power absorbed, BA | When the product is fed from 100 V — 400, When the product is fed from 240 V — 700 |
| Dimensions of the control unit D x S x V, mm | 320х325х140 |
| Mass of control unit, kg | 5.3 |
| Type of pedal | Three-klavic |
| Length of pedal cable, mm | 3200 |
| Overall dimensions of pedal D x S x V, mm | 280х375х70 |
| Mass of pedal with cable, kg | 2.3 |
| Feeding cord length, mm | 1800 |
| Time of establishment of working mode, sec | 2 |
| Pressure hose length, mm | 2000 |
| Mass of pressure hose, kg | 0.12 |
| Maximum volumetric flow, l/min | 4 |
| Gas inlet pressure, MPa | 0,5 |
Supplied components
| Control unit, арт. 26679 | 1 pc. |
| Pedal, арт. 468353.007 | 1 pc. |
| Power cord, арт. 29228 | 1 pc. |
| Monopolar cable, арт. K501-05 | 1 pc. |
| Passive electrode cable, арт. K501-07 | 1 pc. |
| Pressure hose, арт. 302645.006 | 1 pc. |
| Operating Manual | 1 pc. |
| *High pressure pressure editor Argon | 1 pc. |
| *Bunnel capacity for argon | 1 pc. |
Accessories
Alternative names
Argonized, AHVP with argon, Argonoved; ONYX-A - Electric Surgery Generator ONYX-A; ARC PLUS I - Electrosurgical Argonoplasm ARC PLUS I
Medical product code (MI code): 228980. КТРУ: 32.50.50.190-00000450.
The purchase of products starts with a manager ' s consultation. Please describe your tasks or send a list of the items selected, and we will help you to select the components and check the compatibility of the system.
Press "Ask KP" in the product card, write on endo@endo.ru Or call on the phone +7 (843) 207-02-10. Please specify the names or articles of the product, the quantity, organization details and contact details.
Estimated delivery date — from 2 up to 45 It depends on the availability of products, the ordering and the loading of production.
The manager will agree on a specific time frame for your order. If the equipment is required by a specific date, report it when you are in circulation.
Yes Endomedium Develops and produces medical equipment with 1991 Production by the GCO Endomedium+».
The site only contains our products. All the trademarks here are owned by the public Endomedium. Registration and other documents issued under the «Documents».
Yes, our equipment and tools that are required to be registered as medical items have registered documents.
Documents are available in The appropriate section of the site. If you need help with the search, give me the name, model or artiful of the product — a specialist will pick up the documents related to it.
Guarantee and post-insurance maintenance is performed by an authorized service centre Endomedium-Services, licensed for maintenance and repair of medical equipment.
Treatment and maintenance materials are available under the following headings «Service Centre».
Contact the service centre: service@endo.ru, +7 (843) 249-00-45. Please specify the model and serial number of the product, describe the malfunction and leave contact details for feedback. Please attach photographs or videos if possible.
The specialist will specify the course of action and the delivery of the product Requirements for the preparation of service equipment.