Operative hysteroscopy set for large intrauterine lesions
Major gynaecological pathology kit Endomedium for operational hysteroscope the main clinical application of the intake is related to the following by removing large polyps endometry, hysteroscope treatment of sub-mimous mioma and dissecting of the intrauterine partition under direct endoscopy control.
A feature of the system is the ability to simultaneously visualize the pathological site, perform mechanical and electro-surgical manipulations and extract relatively large tissue fragments through an expanded tool channel. This approach is particularly needed in pathologies for which the ability of standard thin tools may not be sufficient.
Clinical use in large intrauterine pathologies
Operational hysteroscope The surgeon is able to directly visualize the education, determine its size, base, myometric and other anatomy patterns and to perform consistent removal of pathological tissue.
In large entities, it is particularly important to use tools of increased diameter and extract larger tissue fragments without having to switch to small caliber tools repeatedly.
Removal of large polyps of endometria
One of the main applications of the recruitment is hysteroscope removal of large polyps endometria. Under visual control, a surgeon can determine the position of the polyp, evaluate the size of its body and base and select the optimal techniques for the separation of the pathological tissue.
Depending on the clinical situation, mechanical dissection, tissue capture and electro-surgery can be used with compatible tools. Once the pathological tissue is separated, the expanded working channel of the system facilitates the removal of large fragments from the uterus.
This principle is consistent with the modern concept of surgical surgery hysteroscope, used by world's leading producers: pathological education is removed under constant visual control and the type of tool is selected according to the size, density and location of the fabric.
Hysteroscope Myotectomy
The kit may be used at hysteroscope treatment of sub-musk mimomatose nodes, Accessible for transcervical endoscopy intervention.
During hysteroscope Myo-ectomy surgeon evaluates the position of myomatose node relative to the uterus and myometrics, determines its intra- and intra-matricular components and is responsible for the progressive dissection or resection of pathological tissue.
In dealing with large miomas, it is particularly important to manipulate larger tissue fragments. The tool channel of the larger diameter allows the use of rigid tools 3 mm For dissecting, seizing, coagulating and removing separated fragments.
Specific equipment hysteroscope Myo-ectomy, the possibility of single-stage or step-by-step removal of the node and the extent of intervention are determined by the doctor depending on the size, localization and degree of intra-maim intramur distribution.
Treatment of intrauterine partition
Another clinical direction is hysteroscope interuterine partition dissection. Endoscopy visualization allows for uterine shape assessment and control of tissue dissecting over the course of intervention.
Mechanical cutting tools or compatible electrosurgery electrodes may be used to handle the partition. The possibility of combining several methods of exposure allows the choice of surgical equipment according to anatomy and a specific clinical task.
Working with large tissue fragments
When large intrauterine units are removed, the surgical task is not only to cut or dissect the pathological tissue, but also to evacuate it from the uterus.
The system is built on an endoscope diameter 26 Fr with direct instrument channel near 4.6 mm. This allows for the use of tools of diameter 3 mm and capture, dissect and extract relatively large tissue fragments under visual control.
A large work channel is particularly relevant for large polyps and myomatose nodes, where separated fragments can significantly exceed the fabrics normally extracted through standard thins hysteroscope Channels.
Mechanical dissipation and electrosurgery
In operational hysteroscope The different stages of intervention may require different methods of exposure to tissue.
Mechanical tools can be used to dissect, mobilize and capture pathological tissue. Electrical surgical tools are used for resection, dissipation and coagulation according to the surgical technique chosen.
Bipolar and monopolar electrosurgery
The system provides the possibility of operating with bipolar and monopolar electrosurgery instruments when connected to compatible electro-surgical equipment.
In modern surgical hysteroscope Bipolar technology is widely used to resect intrauterine pathology hysteroscope Myoectomy, polyectomy and uterus partitioning.
The specific energy, operating mode and uterine expansion environment used shall be in accordance with the instructions for the operation of the applied electro-surgical equipment and tools.
Visual control at all stages of intervention
Direct endoscopy visualization allows the surgeon to monitor the position of the instrument regarding pathological education and surrounding tissue, evaluate the results of the progressive removal of tissue and perform additional dissipation or coagulation if necessary.
This "see and treaty" principle, visualization and treatment in one endoscopy intervention, is one of the main features of modern operational interventions hysteroscope.
Surgical hysteroscope major entities
In the world's leading producer systems, the choice of instrument depends on the size and nature of intrauterine pathology resectoscope The Olympus uses loops of different sizes, including large ones 4-The test shall be performed on the test piece and shall be performed on the test piece resectoscope 26 Fr for medium and large intrauterine pathologies.
Recruitment Endomedium followed by a similar clinical logic: an expanded tool and tools of diameter 3 mm The focus is on surgical work with pathology that requires dissecting, seizing and extraction of larger tissue fragments.
Main clinical challenges
The kit may be used for operational purposes hysteroscope to meet the challenges of:
- treatment of large intrauterine pathological entities;
- by removing large polyps endometry;
- hysteroscope Myo-ectomy;
- treatment of sub-musk mimomatose nodes;
- by the cracking of the intrauterine partition;
- by mechanical dissection of the pathological tissue;
- Electrosurgery and coagulation;
- seized and moved separated fragments;
- by extraction of large tissue fragments through the work channel;
- Surgery under direct endoscopy control.
Recruitment Endomedium for the treatment of large intrauterine pathologies
Major gynaecological pathology kit Endomedium for operational hysteroscope in situations where full-scale instrument work with large intrauterine entities is required.
The system combines endoscopic visualization, the tool channel of the extended diameter and the possibility of mechanical and electro-surgical tools.
Main clinical applications — Large endomemy polyps, sub-musk mimes and intrauterine partitions.
Specific readings and counter-intelligence, intervention techniques, permissible volume of tissue removal, type of electro-surgical energy and compatibility of tools are determined by the registration and operational documentation of the relevant medical products.
| 1 | ![]() | арт. 6010-01, Morcescope EndoGlance® 26 Fr 0°C Toolbox Morcescope EndoGlance®, Tubus diameter 26 Fr, angle of vision 0°, Direct tool 4.6 mm, Workspace length 180 mm |
| 2 | ![]() | арт. 4510-11, external Tow resectoscope 26 Fr Tubus external to the working unit resectoscope 26 Fr, turning point, 2 closed crane |
| 3 | ![]() | арт. 5070-27, l-shaped bipolar electrode, 3 mm L-shaped electrode, bipolar, rigid, dimeter 3 mm, for use with morphoscopes EndoGlance® Direct tool |
| 4 | ![]() | арт. 5070-28, l-shaped monopolar electrode, 3 mm L-shaped electrode, monopolar, rigid, dimeter 3 mm, for use with morphoscopes EndoGlance® Direct tool |
| 5 | арт. 5070-30, biopsicle pinches 3 mm Biopsy pins, hard, diameter 3 mm, for use with morphoscopes EndoGlance® Direct tool | |
| 6 | арт. 5070-42, scissors, bacon-scissors 3 mm Scissors, hard, double-brown, diameter 3 mm, for use with morphoscopes EndoGlance® Direct tool | |
| 7 | арт. 5070-41, scissors are single-branch 3 mm Scissors, hard, single-brained, diameter 3 mm, for use with morphoscopes EndoGlance® Direct tool | |
| 8 | ![]() | арт. 5070-24, direct bipolar needle electrode, 3 mm Igolated electrode, bipolar, rigid, dimeter 3 mm, for use with morphoscopes EndoGlance® Direct tool |
| 9 | арт. 5070-25, direct monopolar needle electrode, 3 mm Igolated electrode, monopolar, rigid, dimeter 3 mm, for use with morphoscopes EndoGlance® Direct tool | |
| 10 | ![]() | арт. 5070-20, spherical bipolar electrode, 3 mm Coagulation electrode, bipolar, rigid, dimeter 3 mm, for use with morphoscopes EndoGlance® Direct tool |
| 11 | ![]() | арт. 5070-21, spherical monopolar electrode, 3 mm Coagulation electrode, monopolar, rigid, dimeter 3 mm, for use with morphoscopes EndoGlance® Direct tool |
| 12 | арт. 5070-31, two-brown pins for capture, 3 mm Fingers, stunning, hard, double-brown, diameter 3 mm, for use with morphoscopes EndoGlance® Direct tool | |
| 13 | арт. 5070-32, single-brown pins for capture, 3 mm Fingers, stunning, tough, single-brown, diameter 3 mm, for use with morphoscopes EndoGlance® Direct tool |