КТРУ 32.50.50.190-00001243 — «The surgical drill/drill management unit, with power from the network." When the operating unit is equipped, it is important to determine whether a separate console is required for the existing motor tool or a set of handles and work tools, which determine the composition of the supply, compatibility of the components and the capabilities of the system in the selected surgical specialization.
In the ruler Endomedium This code is specified for universal electro-mechanical appliances EndoShave® UNI S, арт. 5500-01, and EndoShave® UNI S Pump, арт. 5500-02. They control motor handles and allow configuration to be selected for the tasks of the office.

What makes the surgical instrument control unit
The console sets the mode and speed of the instrument, displays the operating parameters and takes the commands from the pedal. For a doctor, it is possible to control mechanical action within the selected handle and accretion. For engineering, the central component around which a compatible toolbox is formed is the central component.
Item title КТРУ does not mean that any attached handle is both a drill, a saw and shaver. The specific application is determined by the registered performance of the apparatus, the function of the motor handle and the working pad.
EndoShave UNI S and UNI S Pump: Different Performances
Both consoles support one-way rotation and oscillation, one-hand connection and interactive three-word pedal control. Pump has an additional irrigation module. This difference should be taken into account in the planning of the work place and liquid tract composition.
| Parameter | EndoShave UNI S | EndoShave UNI S Pump |
|---|---|---|
| Articule console | 5500-01 | 5500-02 |
| Simultaneous handles | One | One |
| Unilateral rotation | 500–12 000 rpm | 500–13 000 rpm |
| Speed in oscillation mode | 500–6 000 rpm | 500–6 000 rpm |
| ocillation direction shift frequency | 0.5–4.0 Hz | 0.5–4.0 Hz |
| In-line irrigation | Not applicable | Productivity module before 100 mL/min |
| Interface with aspirator/infragger | EndoNet | EndoNet |
| Nutrition | 100–240 V | 100–240 V |
The table shows the characteristics of specific machines from the manufacturer ' s cards, not the mandatory set of entry requirements КТРУ. The permissible parameters for the handle and pad are specified by the operational documentation.
Rotation and oscillation: What is important to a doctor
The working element moves in the chosen direction when rotated unilaterally. The direction is changed periodically in the oscillation mode. The consols allow separate control of the speed and frequency of the change of direction; these values have different units of measurement and should not be combined into one line of the technical task.
The proportional control with pedal allows the key-press speed to be changed. Additional buttons are used to switch mode and change speed settings. Maintaining the latter parameters makes it easier to return to the previously selected configuration but does not replace the settings check before starting.
How to pick up the handles and the workmen's sticks
The UNI S family characteristics list octonolaring, arthropology, neurosurgery, gynaecology, urology and spinal surgery. Each area requires a set of duly agreed. The list of specialties does not in itself mean that one permutation is appropriate for all the interventions listed.
The type of motor handle, the method of installation of the additive, the permissible speed, the working length and the geometry of the cut-off part need to be agreed upon. If the supply or discharge of the liquid is required, the tubes, connections and interconnecting equipment are separately identified. The integrated irrigation module UNI S Pump should not automatically be considered as a substitute for any specialized pump.
Console and ready shaver system — different delivery compositions
The UNI S basic installation includes a console, pedal, power cord, medical lubricant and communications cable. The presence of a specific motor handle, blades and boars needs to be agreed separately.
If the task is to acquire an arthropcopy complex, consider the material about shaver system КТРУ 32.50.50.190-00001244. The handle is removed separately B2, management and interaction with the arthroscopy pump. This helps to distinguish between central unit and functionally complete system procurement.
Documents for comparison with КТРУ
For UNI S and UNI S Pump, the manufacturer ' s website contains a registration certificate РЗН 2025/24727. The specification is prepared by comparing the name of the performance, the composition of the accessories and its performance characteristics КТРУ and conditions of the particular procurement are checked separately: the model does not replace the description of the subject matter of the procurement.
To pick up the machine, tell the specialists Endomedium The list of operations, the details of the handles available and the need for irrigation can be agreed upon on this basis, with no uncertainty about the composition of the supply. Contact us for the setup and commercial offer.