КТРУ 32.50.50.190-00001172 — «Insufflator laparoscopic». Its task is to supply gas to create a working space and maintain the specified pressure at laparoscopic In selecting the apparatus, it is important to evaluate the pressure control, available gas flow, state control and the whole connection.
Laparoscopic insufflator EndoSteam®, арт. 5111-04, is intended for delivery CO₂ The maximum gas delivery rate shall be 50 L/min; specified in the model card КТРУ 32.50.50.190-00001172.

Role insufflator in laparoscopic Operating room
Working space must be preserved by manipulation of tools, aspiration and change of accessories. For a surgeon, it's not just the original pneumoperitoneum that matters, but it's also the control of current pressure, gas flow and system state over the course of the intervention.
EndoSteam Shows the selected and actual parameters, allows the pre-set delivery modes to be selected and the speed to be manually set. This set of functions allows control of the gas contour without replacing the clinical choice of machine machine parameters.
Technical specifications EndoSteam for laparoscopy
| Model Parameter 5111-04 | Characteristics |
|---|---|
| Appointment | Insufflator for laparoscopic Operations |
| Pressure range maintained | 1–30 mmHg |
| Gas delivery rate | 2–50 L/min |
| Pre-established regimes | Minimum, medium, maximum |
| Flow settings | Manual flow rate adjustment |
| Entry pressure | 0,1–0,7 MPa |
| Index | The target and actual pressure, the delivery rate, the volume of gas consumed |
| Warning | Tube burst or compression, absence CO₂ |
| Gas connection | Connected to the central line CO₂; DIN connection 13260-2 |
This shows values from the machine specifications. These are not recommended settings for the patient and do not require the position characteristics КТРУ. The work parameters are selected for clinical task and for the operation manual.
Gas pressure and flow: two different indicators
The pressure shall describe the gas environment in the cavity and the flow rate in the gas supply. The high maximum flow does not mean that the system must be operated with increased intra-abortion pressure.
For a medical organization, it is important to see the actual state of the contour, not just the values introduced EndoSteam The specification should maintain a distinction between the range of settings, the display and the control functions.
Gas tractor: from the source CO₂ up to laparoscopic Access
The kit is selected taking into account the gas source, the inlet pressure, the connection hose, the exit tube and the filter 13260-2. High pressure hose, connecting tube and abacterial filter are present in the assembly.
When fitted with an operating unit, separate checks shall be made on the expendables and their replacement. Absterial filters and silicone tubes selected by purpose, connections and instructions, not just by external diameter.
On the access side, they take into account laparoscopic Troakara The pressure of the valves, connections and the instrument tunnel affects the operation of the system as a whole insufflator review with access used.
Control of non-states
In characteristics EndoSteam The system shall be capable of being capable of being capable of being operated in accordance with the operational documentation.
The presence of an alarm does not preclude checks of the connection, the integrity of the tubes and the readiness of the apparatus before use. The control functions list is convenient to include in the request separately from the pressure and flow ranges.
Laparoscopic Endoscopy insufflator not interchangeable by name
There's also endoscopy performance in the line EndoSteam, арт. 5111-05, The website contains a separate code for the use of the Internet КТРУ. Therefore, when purchasing 32.50.50.190-00001172 Exactly laparoscopic execution 5111-04, Not combining machines only by the general trade name.
Selection and supply insufflator Under КТРУ
For EndoSteam 5111-04 The website contains the FRF registration certificate 2012/13654. In preparing the procurement, the performance, connection requirements and composition of the shipment are compared with the current documentation and the current position КТРУ. The page table is a model introduction, not a substitute for this check.
Contact specialists Endomedium, This will help to harmonize the endoscopy stand configuration and the required accessories insufflator, Gas tractor and equipment in-service kit.