КТРУ 32.50.50.190-00001112 — «System hysteroscope for irrigation/insuffraction hysteroscope The equipment is used to supply the environment necessary for opening and visualizing the system, which requires attention to pressure management, outflow, Tubus compatibility and fluid balance control.
In the catalogue Endomedium This code is specified in historopoppa EndoGyne, арт. 5111-09. It is withdrawn from production; the card recommends replacement for EndoVoid® PV, арт. 5200-01. Consider the relevant pump for the task hysteroscope irrigation.

In the image — EndoVoid PV. The current model card indicates КТРУ 32.50.50.190-00000984. The ability to deliver it in a particular procurement is assessed by requirements and documents without replacing one code with another.
Liquid environment at hysteroscope
Irrigation provides a fluid to the working body through a compatible tool tract. The type of medium, the intake parameters and the conditions of discharge are selected taking into account the intervention and system used hysteroresectoscope Additionally consider the requirements of the operating unit, electrodes and electrosurgery apparatus.
The words "irrigation/insuffle" in the name of the item КТРУ does not mean that any of the equipment in question supplies both liquid and gas. EndoVoid PV is a roller-vacuum pump for liquid irrigation and aspiration insufflator She can't be blamed.
Pump selection for hysteroscope Complex
| What to Check | Data EndoVoid PV | Clarification for hysteroscope |
|---|---|---|
| Profile Mode | Mode provided hysteroscope | Compare parameters of this particular regime |
| Pressure installation and maintenance | 10–200 mmHg | Technical range is not a working pressure recommendation |
| Maximum irrigation | 600 mL/min In mode hysteroscope | Don't put the maximum of other pumping regimes in here |
| Supply and discharge of liquid | Independent roller and vacuum channels | Agree with the Tubus and the motorways used |
| Retaining settings | Energy-dependent storage of pressure and delivery rate | The selected mode and parameters shall be checked before application |
| Acceptable receptacle | Overcrowding control, alarm and unsetting | This is not an automatic measurement of liquid deficit |
| Management | With instrument or pneumatic pedal | Check the accessories and connections |
| Liquid balance accounting | Automatic calculation of model deficit is not stated | Account organization is defined separately |
Model information provided 5200-01 They do not replace the current card КТРУ, The medical professional determines the working arrangements to be allowed.
Overcrowding and liquid balance control
The key to choosing the system is to distinguish these functions. The filling sensor reports the receiving capacity and participates in the intended deactivation of the machine. But the volume of liquid in one vessel does not in itself describe the balance of the environment supplied and removed.
If the technical task requires automatic calculation of the liquid deficit, this function shall be checked as a separate characteristic. It cannot be implied by the presence of a display, a pressure-congestion sensor or a pressure-adjusted device. The organization of the office must provide for a method of balancing the balance, regardless of the name of the selected pump.
Agree to pump hysteroscope and Tubus
The same maximum delivery in two machines does not yet mean the same flow through the instrument used. The value is the tubus channels, the length and section of the lines, connections and the organization of the outflow hysteroscope composition hysteroscope Tools.
Working with resectoscope The system is separate in terms of the irrigation environment and compatibility with the specific electro-surgery regime.
How to plan a replacement EndoGyne
When updating equipment, it is useful to keep the data on the installed complex: Tubus, connections, lines, pedals and receivers. This allows for the creation of a request not only for the new control unit but also for all the items required for its connection and operation.
EndoVoid PV offers several specific modes in one unit hysteroscope, rather than the maximum values for artroscopy, or laparoscopy. The composition of the shipment, the registration documents and the procurement requirements are checked separately for the relevant performance EndoGyne.
Proposal for system hysteroscope irrigation
Specialists Endomedium Please provide a list of the meetings used and the requirements for fluid control. Discuss the selection of the pump for hysteroscope.
If a general review of the irrigation and aspiration channels for the endoscopy operating room is required, see. material on pumping and aspiration. The focus here is on liquid environment and work hysteroscope Complex.