КТРУ 32.50.50.190-00000809 — «The tissue morphulation system." Different clinical configurations may be considered under the general purpose of mechanical tissue fragmentation. Laparoscopic and Urological morcellator Different working tools, speed, access and removal arrangements.
In the ruler Endomedium submitted by MorceCut®, арт. 7001-00, for laparoscopy and MorceCut® Uro, арт. 7100-00, for Urology. Both systems are listed in the cards КТРУ 32.50.50.190-00000809. The choice of execution starts with a clinical task, not a trade name or maximum speed.

How Different laparoscopic and urological morphation
Laparoscopic MorceCut The system describes gynaecological tasks laparoscopy, The use of the material is determined by the readings, the counter-intelligence and the chosen method of extraction.
MorceCut Uro is used for mechanical morphation and evacuation of enulsed prostate tissue. This is a separate phase of endourological intervention: the system works with appropriate tools and aspiration laparoscopic implementation.
Comparison of systems MorceCut Under КТРУ 32.50.50.190-00000809
| Parameter | MorceCut | MorceCut Uro |
|---|---|---|
| Articule | 7001-00 | 7100-00 |
| Application | Laparoscopic Surgery | Endourology |
| Working drive | Electric motor with chopper and sleeves | Engine handle B2, арт. 5052-05 |
| Unilateral rotation | 50–450 rpm | 500–12 000 rpm |
| Scilling | Not specified as operating mode | 500–6 000 rpm; frequency of change of direction 0.5–4.0 Hz |
| Design specificity | Gas exit protection valve, reverses, retreading channel | Replacement blades and interaction with the aspiration and irrigation system |
| Management | Pneumatic pedal | Interactive three-clavic pedal |
| Collaborative equipment | Laparoscopic Access and fabric tools | Ural pump EndoUro and compatible tools access |
The table compares the characteristics of specific models rather than the mandatory position requirements КТРУ. High speed does not in itself mean the advantage of one execution over another: drive and cutting mechanisms are designed for different tasks.
MorceCut for laparoscopy: managed operation of the cutting mechanism
Laparoscopic The system allows the speed of the step-fracture to be adjusted 10 rpm Revers are used to change direction. The design includes a gas exit valve and a stainless steel chimney with a washing channel.
The selection of the set is based on the diameter of the cutting instrument, the external tube and the tools for capturing and feeding the fabric laparoscopic Port.
MorceCut Uro: tissue morphulation and evacuation
The urological performance combines rotation and oscillation B2 The configuration of the cutting window and the geometry of the blade are selected with the task and compatibility with the tool access.
For MorceCut Uro is for interaction with urompa EndoUro®, арт. 5111-11, through EndoShave Link: When selecting the complex, the pump, the communication cable, the aspiration tract and the collection of the tissue recovered will be agreed separately morcellator should not be considered a substitute for the entire irrigation and aspiration system.
Clinical restrictions and tissue handling
Morcellation is performed on reasonable testimony and under visual control laparoscopy The risk of tissue spreading is particularly important, including in the unacknowledged malignant process FDA material on laparoscopic Morcellation; The recommendations of this source do not replace the documents and instructions in force in Russia for a particular product.
The fabric insulation system, if required by the chosen method, is selected according to its purpose and confirmed compatibility. The normal bag for removal of organs cannot automatically be considered as a container designed to operate with the same system morcellator. Separately plan to save and channel material for research.
Complica and processing of components
For MorceCut The card lists the control unit, the electric motor, the chimney, the valve, the fresco, the pedal, the external tubus and accessories MorceCut Uro - console, handle B2, The use of the interactive pedal, communications cable and the intended accessories should be listed separately in the specifications.
Processing methods are defined for each component. The autoclivation of the handle or metal reductor is not automatically applicable to the electronic console. The availability of washing channels and service supplies is taken into account in the organization of reuse.
Selection of the morphocellation system and documents
On the website for laparoscopic MorceCut registration certificate specified РЗН 2024/24236. For urological execution, the specific composition of the system must be compared with the documents used for the console and the handle; in both cases, the conformity of the procurement shall be checked for the relevant item КТРУ and Harmonized Structure.
Contact specialists Endomedium, This will allow the selection of the tissue morphulation system to be used for the task of the separation and the proposal with a complete list of components.