КТРУ 32.50.13.190-00008341 — «The bronchoscopy is rigid." When selecting a product, it is important to distinguish between an optical tube, a bronchoscope tubus and a visualization system: these components work together but have different functions and do not replace each other.
Rigid bronchoscopy EndoGlance® Production Endomedium The following models are examined for comparison with the requirements of the procurement: diameter, length, direction of observation and compatibility with the rest of the equipment 6000-80 and 6000-81 with direction of observation 0° and 30°.

Optic tube in a hard bronchoscopy system
The hard optics transmit the image from the inspection area to the ocular and the endoidocamera EndoGlance The light is supplied from an external source through the light-guide; the optical instrument itself is not a light source.
The individual workplace is selected for the job Bronchoscope tubus and necessary optical tools. The combination is documented: one match of the trademark or external diameter is not sufficient.
Comparison of bronchoscopy EndoGlance 0° and 30°
| Characteristics | 6000-80 | 6000-81 |
|---|---|---|
| Product card | EndoGlance® bronchoscope, 5.5 mm, 0° | EndoGlance® bronchoscope, 5.5 mm, 30° |
| Workspace | 5.5 mm | 5.5 mm |
| Working length according to manufacturer ' s card | 500 mm | 500 mm |
| Observation direction | 0°, Direct | 30°, frontal |
| Angle of the field of vision | 70° | 70° |
| Colour markings | Green | Red |
| Diameter of the ocular | 31.7 mm | 31.7 mm |
The table parameters are taken from the product specifications 500 mm — It is the working length; it cannot be equated without confirmation with another characteristic, such as the length of the optical tube. Full compliance with specific procurement requirements is established after comparison of the same size and operational documentation.
Observation and field of vision are not the same
Angle 0° means the observation of the axis of the instrument 30° The optical orientation changes the direction of the view. The choice depends on the area of inspection and the access system used.
Field of vision 70° The results of the survey are not the same as the results of the survey «30°» and «70°» The data sheet shall be shown in separate rows.
Lighting and video cameras connected
Models 6000-80 and 6000-81 Light-water Connector at Angle 90°. The cards state compatibility with the Olympus light-driving standards, Karl Storz, Wolf and Endomedium. The order shall specify the required switch and its inclusion in the supply and the compatibility of the selected light source with the light source.
| Component | What to check before ordering |
|---|---|
| Bronchoscope tubus | Combination with diameter and working length of the optical unit, design of the connection |
| Endoscopy light guide | Both end of connection, transitions and manufacturer ' s requirements for component combination |
| Endodiedocamera and adapter | Connecting to the ocular 31.7 mm and setting the optical system |
| Lighting | The compatibility of light source with light-guided and optical instrument |
| Storage and processing | Appropriate protective lining and modeled treatments |
The quality of the final image depends on the whole chain: optics, lighting, adapter, camera and monitor. The presence of a certain resolution camera does not in itself confirm the characteristics of the collected system.
Check for procurement by КТРУ 32.50.13.190-00008341
Model cards 6000-80 and 6000-81 code КТРУ. This is the starting point for selecting, but not replacing, the verification of the current position in the EIS and the requirements of the particular procurement.
If the procurement documents require the length of the optical tube 510 mm, the card 500 mm Not sufficient to conclude conformity: documentation of the method of measurement and validation of the parameter is required. No values can be replaced or considered equivalent without confirmation.
There are other performances in the bronchoscopy section, including other diameters and angles of observation, which expand the choice for clinical tasks but should not be automatically included in the same specification «Documents».
Frequent questions about hard bronchos
The optical tube is a complete set of bronchoscopy?
No. The composition of the optics supply and the equipment set for the procedure are different concepts. The tubus, the video system, the light source and the tools need to be agreed separately.
Can the optics be replaced 0° as at 30° No specification change?
Only if the selected performance is permitted by the requirements and compatible with the system. The direction of observation is a separate parameter and not a interchangeable model name.
How to Choose Sterilisation Regime?
In accordance with the current instruction, the selected bronchoscope. Temperatures, pressures, pressures and limitations cannot be imposed in the same way as holistic instruments.
Need an optical for an existing bronchoscopy kit? Let the specialists know Endomedium The data set of the data set, the required direction of observation and the composition of the video system will allow for compatibility to be checked and a harmonized specification prepared.